Modelo 3315 (bajo caudal)


| Bomba | Curva | Descripción | Salida | Motor | Cables | Protección | Admite válvula de limpieza | Altura Metros/Caudal (m3/H) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Potencia | Polos | Tensión | Conex. | Fases | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 60 | 70 | 75 | |||||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 90 kW | 6-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 1069 | 873 | 586 | 286 | 89 | Caudal(m3/H) | |||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 90 kW | 6-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 1180 | 997 | 772 | 457 | 214 | 7 | |||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 90 kW | 6-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 1105 | 899 | 639 | 334 | 111 | ||||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 75 kW | 6-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | SI | 1110 | 770 | 505 | 229 | 8 | ||||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 75 kW | 6-polos | 400V | D | 3-ph | (2x) 4G25-S(2x0.5) | Térmica en bobinado/FLS | SI | 1084 | 893 | 639 | 336 | 95 | ||||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 75 kW | 6-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | SI | 1157 | 997 | 786 | 495 | 216 | ||||||||
| NP/NS | 3315.180 | MT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 250 (10") | 75 kW | 6-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | SI | 1119 | 912 | 675 | 370 | 105 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN150(6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | No | 600 | 481 | 292 | 204 | |||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150 (6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | No | 570 | 420 | 229 | 141 | |||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | No | 572 | 503 | 356 | 157 | 59 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | No | 577 | 515 | 442 | 261 | 68 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | No | 520 | 450 | 391 | 183 | 3 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 105 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 540 | 477 | 416 | 326 | 133 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 85 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 545 | 481 | 420 | 335 | 236 | 32 | |||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150(6") | 85 kW | 4-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | SI | 506 | 440 | 358 | 268 | 166 | ||||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN150(6") | 85 kW | 4-polos | 400V | D | 3-ph | (2x) 4G25+S(2x0.5) | Térmica en bobinado/FLS | SI | 528 | 458 | 399 | 288 | 198 | 93 | |||||||
| NP/NS | 3315.180 | HT | Bomba N 3315; Impulsor: N, Cast iron; Instalación: P/S | DN 150 (6") | 85 kW | 4-polos | 400V | D | 3-ph | (2x) 4G35+S(2x0.5) | Térmica en bobinado/FLS | SI | 491 | 418 | 337 | 241 | 127 | 18 | |||||||